点击显示 收起
the Clinic for Internal Medicine II (M.R., I.E., J.B., R.A., E.M., M.S.), Department of Angiology, University of Vienna, Austria
the Clinic for Radiology (M.R., R.A.B.), Department of Interventional Radiology, University of Vienna, Austria
the Clinic for Neurology (W.L.), University of Vienna, Austria.
Abstract
Background and Purpose— Plaque characteristics are suggested to play a potentially important role as risk factors for poor outcome after carotid artery stenting (CAS). We therefore correlated objectively and subjectively determined carotid plaque morphology with neurological complications after CAS.
Methods— We enrolled 698 consecutive patients undergoing elective CAS from a prospective single-center registry database and classified the preinterventional plaque status according to gray-scale median levels and the standardized Beletsky and Gray-Weale plaque scores. Patients were followed for 30-day neurological complications.
Results— Neurological complications including transient ischemic attack, minor and major stroke occurred in 5.9% (41/698) of the patients. Median gray-scale median, Beletsky and Gray-Weale scores were 45 (interquartile range 25 to 70), 3.0 (IQR 2.0 to 3.0) and 2.0 (IQR 2.0 to 3.0), respectively. None of the scores was significantly associated with adverse outcome adjusting for traditional risk factors, medication, preinterventional symptoms, degree of stenosis, contralateral occlusion and use of cerebral protection, neither with respect to all neurological complications nor with respect to stroke and death (all P>0.05).
Conclusions— Plaque echolucency measured by objective and subjective grading did not identify patients with an increased risk of peri-interventional neurological events. Evaluation of plaque echolucency therefore cannot be recommended for risk stratification in CAS patients.
Key Words: carotid artery plaque stents stroke
Introduction
Identifying powerful determinants for adverse outcome after carotid artery stenting (CAS) is crucial to lower the risk of the procedure and to increase the benefit of the patient compared with medical treatment alone.1–4 Among the panel of potential risk factors, plaque characteristics are suggested to play a potentially important role. Biasi et al recently reported a significant association between neurological outcome after CAS and plaque morphology using a quantitative computer-assisted index of echogenicity called gray-scale median (GSM), suggesting that patients with echolucent plaques have an increased risk for complications.5 In addition to GSM analysis, several visual scores have been described for plaque characterization, but their value in the identification of high-risk plaques before carotid revascularization has not been determined yet.6,7 Therefore, we investigated the association between plaque morphology, measured by GSM and visual scores, and occurrence of neurological events and mortality after elective CAS.
Materials and Methods
We enrolled 698 consecutive patients from a prospective single-center registry database who underwent elective carotid stent placement between January 1997 and June 2005 by 3 operators. Candidates were initially identified on the basis of their clinical status and the presence of an angiographically documented stenosis of 70% or more (NASCET) and were included in the registry before treatment.8 Indications, premedication and technical details of the stent placement procedure are described in previous reports.9–12 Previously, we assessed the effect of patient age, individual learning curve of the physician performing the intervention, contralateral high-grade ICA stenosis or occlusion and the use of protection devices on the neurological outcome after CAS in partly overlapping patients.9–12
Ultrasound Stenosis Grading and Plaque Evaluation
Ultrasound (US) was performed 1 day before treatment by using a XP10 scanner (Acuson) with a 5-MHz-linear probe or an Acuson Sequoia scanner (Siemens) with a 14-MHz-linear probe by 2 medical technical assistants and supervised by 1 of the authors (E.M.). B-mode settings were adjusted and standardized by using a maximum dynamic range (60 dB) and by setting the gain to ensure an almost noiseless vessel lumen (blood) and an echo-dense area of adventitia. Images were stored in tagged-imaged files format and then standardized as described previously on a personal computer by using Adobe Photoshop 7.0 (Adobe Systems) to calculate the GSM score.5,13 Additionally, the standardized images were classified in consensus by 2 observers (M.R., I.E.), not involved in the image acquisition, according to the scores of Beletsky and Gray-Weale.6,7 The score of Beletsky has 3 stages: (1) soft plaque/organized thrombus, (2) intraplaque hemorrhage/fatty deposition, and (3) fibrosis/densely calcified plaques.6 Plaques classified in group 1 exhibited a lower density (&2 times of the blood density) than group 2, which in turn had a lower density than group 3 (as dense as the surrounding connective tissue with/without additional acoustic shadowing).6 The score of Gray-Weale uses the following stages: (1) dominantly echolucent, (2) substantially echolucent with small areas of echogenicity, (3) dominantly echogenic with small areas (<25%) of echolucency, (4) uniformly echogenic, and (5) invisible because of heavy calcification.7
Neurological Evaluation
Neurological history and examination were routinely performed the day before, and the day after CAS by independent neurologists. Baseline cranial CT was mandatory in all patients. If neurological events were suspected, clinical evaluation with cranial CT was performed immediately. A transient ischemic attack (TIA) was defined as a focal ischemic neurological deficit with abrupt onset that resolved completely within 24 hours. A minor stroke was defined as a focal neurological deficit that lasted >24 hours and had a National Institutes of Health Stroke Scale (NIHSS) score 4.14 A major stroke was defined as a focal neurological deficit that lasted >24 hours and had a NIHSS score >4.14
Statistical Methods
Data are given as counts (percentages) or medians (interquartile range –range from the 25th to the 75th percentile). Univariate analyses were performed applying Yates corrected 2 statistics, exact tests or Mann Whitney U tests, as appropriate. Multivariable logistic regression analysis was applied to assess the association between plaque morphology and neurological complications to adjust for potential confounding factors and to address potential interactions. A probability value <0.05 was considered statistically significant. Analyses were performed using SPSS (Version 12.0) or Stata (release 8.0).
Results
Patients
Baseline patient characteristics and technical data of stent placement are presented in Table 1. Neurological complications occurred in 5.9% (41/698). Rates of TIAs, minor and major strokes were 3% (21/698), 1.3% (9/698) and 1.6% (11/698), respectively. Combined 30-day stroke-and-death rate was 2.9% (20/698). Two fatal strokes occurred in 2 patients undergoing unprotected CAS, none in the group undergoing protected CAS. Segregating neurological complication rates for symptomatic and asymptomatic patients, we observed rates of TIAs, minor and major strokes of 3.8% (8/208) versus 2.7% (13/490), 1.4% (3/208) versus 1.2% (6/490) and 3.4% (7/208) versus 0.8% (4/490), respectively (P=0.072).
Plaque Characteristics and Complications
In 94 patients (13%) GSM levels and Beletsky score could not be calculated because of poor imaging quality, and the Gray-Weale score could not be calculated in 4 patients (0.6%). Median GSM, Beletsky and Gray-Weale scores were 45 (IQR 25 to 70), 3.0 (IQR 2.0 to 3.0) and 2.0 (IQR 2.0 to 3.0). By univariate analyses none of the indices was significantly different in patients with and without events with respect to all neurological complications or death (P>0.05).
GSM levels were then categorized as low (<25) and high (25) as reported previously.5 The frequencies of neurological complications and strokes in patients with low versus high GSM levels were 2.7% (4/146) versus 6.6% (30/458; P=0.13) and 2.1% (3/146) versus 3.1% (14/458; P=0.73), respectively.
Being aware of several potential confounders we applied multivariable logistic regression analyses, which demonstrated no significant association of plaque morphology with neurological outcome (Table 2). Furthermore, we tested for interaction by log-likelihood-ratio tests and multiplicative interaction terms between use or nonuse of cerebral protection, neurological outcome and the GSM levels and the 2 predefined scores, without detecting a significant effect modification or change of the model fit. Similarly, no interaction for symptomatic versus asymptomatic patients was observed. Including the 94 patients with inconclusive GSM scores attributable to heavy calcification as a separate category, we observed no significantly increased risk for neurological complications or stroke in the multivariable model (all P>0.05).
Discussion
We investigated a potential influence of carotid plaque morphology on the neurological outcome after CAS. Neither objective GSM measurement nor subjective grading according to standardized scores was significantly correlated to adverse neurological outcome. These findings are in contrast to the only previously published study by Biasi et al, who reported a significantly higher risk for neurological complications of plaques with a GSM below 25.5
Several issues may account for this discrepancy: Biasi et al performed a multicenter trial and included the images of 11 participating centers, which were recorded on video tape (analogue) and then transferred onto a personal computer (digital) for further standardization, thus potentially resulting in a loss of image information.5 The images used in our study were stored immediately as digital images interfaced with the ultrasound machine and therefore could be directly analyzed without further transfer procedures. Besides these potential differences in image quality, a significant influence of investigator and laboratory on the evaluation of carotid stenosis is well known, suggesting a more homogenous dataset obtained by our single-center trial compared with the multicenter (11 different laboratories and US machines) study by Biasi.5,15 Furthermore, a mathematical limitation of the study by Biasi et al is the relatively low number of events (23/418 patients), resulting in high standard deviations of GSM values, which might have caused false-positive results—in the present study the sample size and number of events was almost double resulting a smaller confidence intervals and higher predictive power.5
A relatively high number of low-quality images (ie, caused by heavily calcified plaques) had to be excluded from further analyses both in our study as well as in the report by Biasi.5 Biasi et al excluded 16% of patients and we also had to exclude 13%. However, even in accurately executed US studies these limitations cannot be completely eliminated based on the examination technique and the advanced atherosclerosis in CAS eligible patients.
Limitations
Some limitations of the present study have to be acknowledged. Although the number of participants and number of events was quite large, false-negative results still cannot be completely ruled out. Furthermore, the time interval for data acquisition was long, and considerable technical developments may have influenced our findings. Nevertheless, we tried to statistically account for presumably important changes, like the introduction of cerebral protection devices, and found a consistent lack of association between GSM levels and the Beletsky and Gray-Weale scores, respectively, and neurological outcome.
Conclusions
Plaque echolucency measured by objective and subjective grading did not identify patients with an increased risk of peri-interventional neurological events. Evaluation of plaque echolucency therefore cannot be recommended for risk stratification in CAS patients.
Acknowledgments
Disclosures
None.
References
Bergeron P, Roux M, Khanoyan P, Douillez V, Bras J, Gay J. Long-term results of carotid stenting are competitive with surgery. J Vasc Surg. 2005; 41: 213–221.
Coward LJ, Featherstone RL, Brown MM. Safety and efficacy of endovascular treatment of carotid artery stenosis compared with carotid endarterectomy: a Cochrane systematic review of the randomized evidence. Stroke. 2005; 36: 905–911.
Yadav JS, Wholey MH, Kuntz RE, Fayad P, Katzen BT, Mishkel GJ, Bajwa TK, Whitlow P, Strickman NE, Jaff MR, Popma JJ, Snead DB, Cutlip DE, Firth BG, Ouriel K; Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy Investigators. Protected carotid-artery stenting versus endarterectomy in high-risk patients. N Engl J Med. 2004; 351: 1493–1501.
Kastrup A, Groschel K, Schulz JB, Nagele T, Ernemann U. Clinical predictors of transient ischemic attack, stroke, or death within 30 days of carotid angioplasty and stenting. Stroke. 2005; 36: 787–791.
Biasi GM, Froio A, Diethrich EB, Deleo G, Galimberti S, Mingazzini P, Nicolaides AN, Griffin M, Raithel D, Reid DB, Valsecchi MG. Carotid plaque echolucency increases the risk of stroke in carotid stenting: the Imaging in Carotid Angioplasty and Risk of Stroke (ICAROS) study. Circulation. 2004; 110: 756–762.
Beletsky VY, Kelley RE, Fowler M, Phifer T. Ultrasound densitometric analysis of carotid plaque composition. Pathoanatomic correlation. Stroke. 1996; 27: 2173–2177.
Gray-Weale AC, Graham JC, Burnett JR, Byrne K, Lusby RJ. Carotid artery atheroma: comparison of preoperative B-mode ultrasound appearance with carotid endarterectomy specimen pathology. J Cardiovasc Surg. 1988; 29: 676–681.
Hobson RW 2nd, Howard VJ, Brott TG, Howard G, Roubin GS, Ferguson RD; For the CREST Executive Committee. Organizing the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST): National Institutes of Health, Health Care Financing Administrating, and industry funding. Curr Control Trials Cardiovasc Med. 2001; 2: 160–164.
Ahmadi R, Willfort A, Lang W, Schillinger M, Alt E, Gschwandtner ME, Haumer M, Maca T, Ehringer H, Minar E. Carotid artery stenting: effect of learning curve and intermediate-term morphological outcome. J Endovasc Ther. 2001; 8: 539–546.
Ahmadi R, Schillinger M, Lang W, Mlekusch W, Sabeti S, Minar E. Carotid artery stenting in older patients: is age a risk factor for poor outcome J Endovasc Ther. 2002; 9: 559–565.
Sabeti S, Schillinger M, Mlekusch W, Nachtmann T, Lang W, Ahmadi R, Minar E. Contralateral high-grade carotid artery stenosis or occlusion is not associated with increased risk for poor neurologic outcome after elective carotid stent placement. Radiology. 2004; 230: 70–76.
Boltuch J, Sabeti S, Amighi J, Dick P, Mlekusch W, Schlager O, Ahmadi A, Minar E, Schillinger M. Procedure-related complications and early neurological adverse events of unprotected and protected carotid stenting: temporal trends in a consecutive patient series. J Endovasc Ther. 2005; 12: 538–547.
Sabetai MM, Tegos TJ, Nicolaides AN, Dhanjil S, Pare GJ, Stevens JM. Reproducibility of computer-quantified carotid plaque echogenicity: can we overcome the subjectivity Stroke. 2000; 31: 2189–2196.
Brott T, Adams HP Jr, Olinger CP, Marler JR, Barsan WG, Biller J, Spilker J, Holleran R, Eberle R, Hertzberg V. Measurements of acute cerebral infarction: a clinical examination scale. Stroke. 1989; 20: 864–870.
Alexandrov AV, Vital D, Brodie DS, Hamilton P, Grotta JC. Grading carotid stenosis with ultrasound. An interlaboratory comparison. Stroke. 1997; 28: 1208–1210.