[摘要]目的:本实验采用高效液相色谱法测定环丙贝特及其有关物质的含量。方法:色谱柱为C18柱(4.6mm×150mm,5μm),流动相为0.01mol/L醋酸铵[pH为(3.8±0.1)]-乙腈(1∶1),检测波长为230nm。结果:线性浓度范围为0.02~0.2mg/ml,平均回收率为(100.6±0.6)%(n=5),精密度RSD为0.7%。结论:方法简便、快速、准确。 Determination of ciprofibrate and its related substances by HPLC WANG Jun-qiu,ZHANG Jie-ping,ZHANG
Han,YU Li [Abstract]Objective:To establish a HPLC method for
determination of ciprofibrate and its related substances in tablets.Methods:A C18
column(4.6mm×150mm,5μm),a mobile phase consisting of 0.01 mol/L ammonium acetate
solution (pH was adjusted to 3.8±0.1 with acetic acid)∶acetonitrile=1∶1 and a UV
detector at 230 nm were adopted.Results:The established method has a linear limit of 0.02~0.2
mg/ml,a mean recovery of ciprofibrate of (100.6±0.6)%(n=5) and a RSD of 0.7%.Conclusion:A
simple,rapid,and precise HPLC method for determination of ciprofibrate and its related
substances was established. 环丙贝特(ciprofibrate)是用于降血脂的药品,原质量标准中含量测定及有关物质的测定均采用HPLC法[1],但采用不同的流动相。现经实验,对流动相进行了改进,改进后的方法可同时测定含量及有关物质,方法简便准确。 材料与方法 1 仪器 结 果 1 含量测定 表1 3批样品含量测定比较 |
批 号 | 旧流动相测定结果(%) | 现流动相测定结果(%) |
990301 | 100.5 | 100.3 |
990302 | 100.4 | 99.91 |
990303 | 100.5 | 100.5 |
2 有关物质测定 照含量测定项下的高效液相色谱法测定。取本品10片,精密称定适量(相当于环丙贝特20 mg),置100ml量瓶中,加流动相溶解并稀释刻度,作为样品溶液,作为供试品溶液;取该溶液1ml置100ml量瓶中,加流动相稀释至刻度,摇匀,作为限度对照溶液。取对照溶液10μl 注入液相色谱仪,调整仪器灵敏度,使主成分的峰面积能满足正确积分的要求。精密吸取供试品溶液和限度对照溶液各10μl,分别进样,记录色谱图至主成分峰保留时间的6倍。环丙贝特甲酯、环丙贝特乙酯的保留时间分别为环丙贝特的保留时间的3.5和5.0倍,按外标法计算供试品中杂质的含量,供试品溶液的色谱图中环丙贝特甲酯、环丙贝特乙酯面积之和不得大于限度对照溶液主成分的峰面积。 讨 论 因经测定环丙贝特甲酯与环丙贝特乙酯的校正因子均约为1.0,故修订后的标准不再采用环丙贝特甲酯与环丙贝特乙酯外标法测定有关物质,而采用样品的自身对照法测定[2]。 [作者简介]王俊秋(1964-),女,副主任药师,药学学士,从事药品检验工作。 [参考文献] [1]卫生部药政局、中国药品生物制品检定所.中国药品检验标准操作规范[S].北京:中国医药科技出版社,1996.65-66. 收稿日期:2000-03-27 修回日期:2000-08-23 |