点击显示 收起
摘要 目的:测定复方健疗霜中曲安奈德、盐酸苯海拉明和硝酸咪康唑的含量。
Determination
of Three Components of Compound Fei Luhua
and Nie Xiaochun Abstract Objective:To separate and determine three
constituents including triamcinolone acetonide,diphenhydramine hydrochloride
and miconazole nitrate in Compound Jianliao Cream.Method:A HPLC method was used chromatographic conditions included
Shim-pack CLC-phenyl column and the mobile phase consist of methanol
and water(70∶30).The detection wavelength was 230 nm.Results:The separation and determination of three constituents
could be accomplished simultaneously.The calibration curves were
linear in the range of 0.020~0.080 g.L-1 for triamcinolone acetonide;0.080~0.320 g.L-1 for diphenhydramine hydrochloride;0.160~0.640 g.L-1 for miconazole nitrate.The average
recoveries of triamcinolone acetonide,diphenhydramine hydrochloride,miconazole
nitrate were 100.4%(RSD=1.02%),100.6%(RSD=0.91%),100.5%(RSD=0.60%)respectively.Conclusion:This method was found to be simple,quick and accurate
for simultaneous determination of the three constituents in Jianliao
Cream. 复方健疗霜是由曲安奈德(Triamcinolone acetonide)、盐酸苯海拉明和硝酸咪康唑等多种成分制成的软膏。主要用于治疗顽癣,对湿疹、皮炎也有一定的疗效。已见有分别测定曲安奈德、盐酸苯海拉明和硝酸咪康唑的液相色谱方法[1~4]。三组分的色谱行为差异较大,迄今未见有同时测定三组分的液相色谱方法。本文在对多种色谱体系进行筛选的基础上,建立了以苯基硅烷键合硅胶为填充剂的高效液相色谱法,同时分离和测定复方健疗霜中三组分,并用于制剂的质量控制,切实可行,简便准确。 1 仪器与试药 Waters 510泵、490多波长紫外检测器、740色谱数据处理机。 2 色谱条件 色谱柱:Shim-pack CLC-phenyl(10 μm,6.0 mm×150 mm),日本岛津公司。检测波长:230 nm;流速:1.0 mL.min-1;柱温:室温;进样量:20 μL;流动相:甲醇-水相(三乙胺2 mL,加水至300 mL,磷酸调pH 7.6)(70∶30) 3 方法与结果 3.1 对照品储备液的配制 精密称取各对照品适量,加甲醇溶解,制成曲安奈德0.5
g.L-1、盐酸苯海拉明2 g.L-1、硝酸咪康唑4 g.L-1的对照品溶液。 |
图1 样品色谱图 3.3 线性回归 精密量取对照品储备液2.0、3.0、4.0、5.0、6.0、7.0、8.0
mL,用甲醇分别稀释至50 mL,精密量取此液20 μL注入色谱仪,测定,按外标法以峰面积A对浓度C(g.L-1)回归,曲安奈德,盐酸苯海拉明,硝酸咪康唑的线性范围分别为:0.020~0.080、0.080~0.320、0.160~0.640
g.L-1,回归方程分别为: 表1 样品含量测定结果(%,n=2) |
批号 | 曲安奈德 | 盐酸苯海拉明 | 硝酸咪康唑 |
9609161 | 102.6 | 99.2 | 104.4 |
9609158 | 103.2 | 99.6 | 103.0 |
9609156 | 102.4 | 97.8 | 102.8 |
4.1 色谱柱的选择 实验过程中,曾分别尝试在十八烷基硅烷键合硅胶、辛烷基硅烷键合硅胶、硅胶、氰基等不同填料的色谱柱上考察曲安奈德、盐酸苯海拉明和硝酸咪康唑的色谱行为。由于三组分极性相差较大,在上述有些填料柱上选择适当的流动相,虽可分离这三组分,但不是保留时间过长,就是有基质的干扰。本文经反复筛选,确定了在苯基柱上,以甲醇-水相(70∶30)为流动相的色谱体系,分离本品中的三组分,可排除基质的干扰,分析时间在20
min可完成。 作者单位:武汉市药品检验所 430012 参考文献 1 张先洲,罗顺德,张帆等.HPLC测定硝酸咪康唑栓剂和霜剂的含量.药物分析杂志,1993,13(3):198 (本文于1998年2月23日收到) |