Study on the Determination and Stability of 2-Chlor-4-Nitrophenylene-β-D-Galactose Glycoside(CNP-Gal)and 2-Chlor-4-Nitrophenylene-N-Acetoacetic-β-D-Glucosaminide(CNP-NAG)by HPLC Wang Yujie
and Zhang Li Abstract Objective:This paper
reported the determination of CNP-Gal、CNP-NAG and study on their stability
by HPLC.Methods:The chromatographic conditions
were column,Shim-Pack CLC-CN(6.0 mm×150 mm);mobile phase,dichloromethane-methanol-hexane-dioxane(4∶1∶6∶1);flow
rate,1 mL.min-1;multiwavelength
detector at 290 nm;internal standard,2,4-dinitrophenylhydraxine(It
was a internal standard,when CNP-Gal was determined) and CNP-Gal(It
was a internal standard,when CNP-NAG was determined).Results:The average recovery of CNP-Gal
and CNP-NAG were 99.98%、99.97% separately.The RSD
of the recovery is <1.0%.Conclusion:CNP-Gal and CNP-NAG were found
that they were stable under 4000lx(42 hours) and 60 ℃(504 hours),but
they willdecompose quickly in the polar solvents. 2-氯-4-硝基苯基-β-D-半乳糖苷(CNP-Gal)和2-氯-4-硝基苯基-N-乙酰基-β-D-氨基葡萄糖苷(CNP-NAG)为肾脏疾病的早期诊断药品。CNP-Gal和CNP-NAG于1988年及1984年分别由美国、日本等国研制成功。我国于1990年研制成功。经查阅近8年的美国《化学文摘》及国内有关刊物,其测定方法均未见报道。为此,我们建立了上述2种诊断药品的测定方法。现报道如下: 1 仪器与试剂 日立L-6200型高效液相色谱仪,检测器为日立2000-10型紫外/可见光检测器,岛津C-R1A数据处理机,色谱柱为岛津Shim-Pack
CLC-CN柱(10 μm,6 mm×150 mm)。 2 色谱条件 岛津Shim-Pack CLC-CN柱,二氯甲烷-甲醇-正己烷-二氧六环(4∶1∶6∶1)为流动相,测定CNP-Gal含量时,以2,4-二硝基苯肼为内标物;测定CNP-NAG含量时,以CNP-Gal为内标物,检测波长为290 nm,流速为1 mL.min-1,进样20 μL,室温。在上述条件下,样品的典型分离情况见图1、2,有关色谱参数见表1。 |
图1 CNP-Gal与2,4-二硝基苯肼的分离图 | 图2 CNP-NAG与CNP-Gal的分离图 |
|
| 2,4-二硝基苯肼 | CNP-Gal | CNP-NAG | |
保留时间/min | 4.37 | 7.72 | 10.29 | |
理论板数 | 2740 | 1800 | 3020 | |
分辨率 | 6.7 | 2.2 |
3.1 CNP-Gal的线性范围 精密称取CNP-Gal对照品50、40、30、20、10
mg,各加二氯甲烷-甲醇(2∶1)混合液80 mL,超声振荡使溶解后,再各加正己烷-二氧六环(6∶1)混合液使成100
mL,作为对照品溶液。另精密称取内标物2,4-二硝基苯肼为50 mg,用乙酸乙酯溶解并稀释至50
mL,作为内标溶液。精密量取上述各对照品溶液5 mL,分别置10 mL量瓶中,各精密加入内标溶液2
mL,用流动相稀释至刻度,摇匀,进样20 μL。以3次测定的峰面积平均值的数据作回归方程。结果为: 4 校正因子的测定 取CNP-Gal与2,4-二硝基苯肼的混合标准液(CNP-Gal
0.15 mg,2,4-二硝基苯肼0.2 mg.mL-1),进样20 μL,5次测得的校正因子平均值为0.460,RSD为0.73%。 5 回收实验 精密称取各对照品及内标物适量,配制成5种不同浓度的对照品及内标物的混合溶液,摇匀,进样20 μL,计算回收率。结果CNP-Gal与CNP-NAG的平均回收率分别为99.98%、99.97%,RSD分别为0.72%和0.46%。 6 溶液的稳定性试验 将样品置于无色透明的量瓶中,每隔1 h测定1次,共考察了4 h,结果表明,溶液在4 h之内,其峰面积基本不变。 7 样品的测定 以建立的上述方法测定多批样品,并与外标法做比较,实验表明,内标法和外标法测得的结果基本一致。结果见表2。 表2 样品测定结果(%,n=3) |
名 称 | 批 号 | 内标法 | 外标法 |
CNP-Gal | 920320 | 100.2(0.72) | 99.3 |
920410 | 99.8(0.34) | 99.5 | |
920417 | 99.6(0.19) | 99.1 | |
CNP-NAG | 920603 | 99.5(0.65) | 99.4 |
920807 | 99.4(0.38) | 99.3 | |
920924 | 99.4(0.58) | 99.7 |
注:括号内为RSD(%) 8 样品稳定性的加速试验 8.1 光照对样品稳定性的影响 分取CNP-Gal(批号为920417)和CNP-NAG(批号为920807)样品,置光照度为4000lx下直接照射42
h,每隔数小时测定1次。实验表明,上述2种诊断药品对光较稳定。 9 讨论 9.1 色谱系统的选择 CNP-Gal和CNP-NAG 2种诊断药品在如水、甲醇等的强极性溶液中易分解成糖苷和2-氯-4-硝基酚(CNP),致使溶液变黄。故此,将分析方法选择为氰基柱的正相高效液相色谱法。在建立分析条件时,曾比较了多种不同比例的氯仿-甲醇-正己烷系统,均未得到良好的分辨率。同时,还选择了数种其他流动相系统(如氯仿-乙腈-正己烷系统、二氯甲烷-甲醇-正己烷系统等),仍不理想,最后,将流动相系统选定为:二氯甲烷-甲醇-正己烷-二氧六环(4∶1∶6∶1),可得到良好的分辨率。 作者单位:天津市药品检验所 300070 (本文于1998年5月5日收到) |