摘 要:目的 测定格列本脲胶囊中残留有机溶剂二甲基甲酰胺的含量。方法 采用气相色谱法,氢火焰离子化检测器(FID),以二甲基亚砜为溶剂,四氢呋喃为内标,采用毛细管柱,以100%二甲基聚硅氧烷为固定相,柱温150℃维持14min,以40℃.min-1的速率升温至200℃,维持12min,实现了各组分的基线分离。结果 3批格列本脲胶囊中二甲基甲酰胺的残留量均低于限量(0.088%)。结论 经方法学试验验证,该方法灵敏、准确、可信,适用于本品有机溶剂残留量的测定。
Determination of N,N-dimethyl formamide in micronazed gilibenclamide capsules by gas chromatography WANG Wei(Tianjin
Institute for Durg Control,Tianjin 300070,China) Abstract:OBJECTIVE To determine the content of N,N-dimethyl-formamide,the residual organic volatile solvents,in micronazed gilibenclamide capsules.METHODS Dissolved in dimethyl sulphoxide,2 μL sample solution was injected on a DB-1 (100% dimethyl-polysiloxane) sillica capillary column using nitrogen as the carrier gas.Keep the initial temperature at 150℃ for 14 min,then it was raised to 200℃ at the rate of 40 ℃*min-1,sustained for 12 min.The injection port and FID detector were 210℃ and 240℃.Under this condition,N,N-dimethyl formamide and the internal standard tetrahydrofuran were separated completeh.RESULTS The linear range of N,N-dimethyl formamide was 35.19~28.15 μg.mL-1,and the LOD was 8.8 μg.mL-1.The precisions was 1.9%.The recovery of N,N-dimethyl formamide was 101.4%.Three batches of sample were analysed.CONCLUSION After validation,the method was proved to be accurate,sensitive and reliable.It is quite suitable to be used in the analysis of the N,N-dimethyl formamide in micronazed gilibenclamide capsules.
|
作者单位:王卫(天津市药品检验所,天津
300070) 参考文献: [1]中国药典1990年版.药典注释[S],1990:469. 收稿日期:2000年6月27日 出版日期:2001年2月8日 |
原载于《中国药学杂志》2001 Vol.36 No.2 P.120-122